Note that there is an exit delay before the system is armed in any
mode. The bypass will only take place if the zone is not ready when
the exit delay is over and the system actually arms itself.
When a zone is Auto-Bypassed, it will be automatically restored the
next time you arm or disarm the system. The auto-bypass is recorded
in the event log as "ZONE NAME BYPASSED".
To prevent any zone from being bypassed unintentionally, you should
always look for "SYSTEM OK" on the display before arming and
leaving the premises.
When arming a different area, in Auto-Bypass mode, all zones in that
area must be ready. If any zones are not ready, you must manually
Bypass those zones before arming that area.
The Auto-Bypass feature can be disabled if you do not want the system
to automatically bypass open zones. If the auto-bypass feature is
disabled, the alarm will sound if a zone is open and the system is
armed.
NOTE: The Auto-Bypass feature is disabled on UL Listed
Installations.
9 = RESTORE
Restoring a zone puts it back on active duty in the system. When
restored, the Bypassed indication will no longer be displayed on the
status line and the zone will be checked for alarm and trouble
conditions.
To restore a zone, from the top-level display, press 2 on the console
keypad, then 9 for restore.
Enter the zone number followed by the ' # ' key, or use the arrow keys
to select the zone. Press ' 0 ' as the first key to restore all zones. The
0 = ALL choice is removed once a digit key or the down arrow is
pressed. After the zone or all zones is entered, you will be prompted
to enter your code.
Restoring Zones
14 Omni Owner's Manual